LOW SMOKE
Enhancing fire safety by reducing smoke emissions, protecting lives, and preserving critical infrastructure.
Introducing “APAR Anushakti,” our groundbreaking product created using cutting-edge Electron Beam Technology (E-beam). This innovative wire surpasses conventional ones by offering a remarkable 50% increase in current carrying capacity as well as enhanced resistance to higher temperatures. With its superior performance and eco-friendly nature, APAR Anushakti establishes itself as the safest house wire option in India.
In response to the significant demand for APAR Anushakti wires, which are manufactured using the E-beam technology, we have introduced a new range of wires called HR FR LSH (Flame Retardant Low Smoke Zero Halogen) to address fire hazards. These wires offer several significant advantages. Firstly, they provide enhanced fire safety by resisting the spread of flames, helping to prevent the escalation of fires in electrical installations. Additionally, these wires emit low levels of smoke in the event of a fire, improving visibility and facilitating safe evacuation. Another advantage is that HR FR LSH wires are manufactured without halogens, reducing the release of toxic gases and corrosive substances during combustion, making them safer for both people and property. Overall, these wires prioritize safety, minimize fire-related risks, and offer a reliable solution for electrical installations.
Enhancing fire safety by reducing smoke emissions, protecting lives, and preserving critical infrastructure.
Minimizing environmental impact, ensuring safety, and promoting sustainable electrical systems
The insulation with a higher operating Temperature of 105 ° C
With E-beam irradiated FR PVC insulation, it avoids short circuits & electric shock
High Oxygen and Temperature Index make it fire retardant and self-extinguishing. It doesn't catch fire on its own.
The insulation does not quickly melt while in contact with a hot object
Effective defense against termites with advanced anti-termite solutions
Minimal leakage, maximizing efficiency and sustainability
Energy-efficient cable, powering sustainability with every connect
NOMINAL AREA OF COPPER CONDUCTOR | CONDUCTOR CONSTRUCTION | THICKNESS OF INSULATION (NOMINAL) | APPROX OVERALL DIAMETER | CONDUCTOR RESISTANCE (MAX) PER KM @20 C | IN CONDUIT / TRUNKING | UNENCLOSED-CLIPPED DIRECTLY TO SURFACE OR ON CABLE TRAY |
---|---|---|---|---|---|---|
Sq.mm | Nos / mm | mm | mm | Ohms | Amps | Amps |
0.75 / Class 5 | 24 / 0.2 | 0.6 | 2.20 | 26 | 11 | 16 |
1 / Class 2 | 7 / 0.43 | 0.7 | 2.70 | 18.1 | 16 | 24 |
1 / Class 5 | 32 / 0.2 | 0.6 | 2.40 | 19.5 | 16 | 24 |
1.5 / Class 2 | 7 / 0.53 | 0.7 | 3.00 | 12.1 | 20 | 32 |
1.5 / Class 5 | 30 / 0.25 | 0.7 | 2.85 | 13.30 | 20 | 32 |
2.5 / Class 2 | 7 / 0.67 | 0.8 | 3.60 | 7.41 | 27 | 44 |
2.5 / Class 5 | 50 / 0.25 | 0.8 | 3.50 | 7.98 | 27 | 44 |
4 / Class 2 | 7 / 0.85 | 0.8 | 4.10 | 4.61 | 36 | 58 |
4 / Class 5 | 56 / 0.3 | 0.8 | 4.0 | 4.95 | 36 | 58 |
6 / Class 2 | 7 / 1.04 | 0.8 | 4.70 | 3.08 | 47 | 74 |
6 / Class 5 | 84 / 0.3 | 0.8 | 4.50 | 3.30 | 47 | 74 |
Core: Single Core
Insulation: HR FR PVC
Length: 90 m, 100 m & 180 m
Colour: Red, Green, Blue, Black, White, Yellow (Available in custom colours)