- 1Class 2 / Class 5 copper conductorElectrolytic-grade annealed bare copper, stranded for flexibility
- 2E-beam cross-linked HR FR-LSH insulationHeat-resistant to 105°C, flame-retardant, low smoke and zero halogen
- 3Printed identification & ISI markingGrade, size, 1100 V, IS 694 and BIS licence number
APAR Anushakti HR FR LSH
Anushakti HR-FR-LSH is the grade searched for as HR FR LSH wire, HRFR LSH wire or low smoke heat resistant wire. It combines the two upgrades in one insulation: heat resistance for circuits that run warm, and a low-smoke, low-halogen compound for buildings where smoke would block an escape route. It is the flagship PVC-based house wire in the APAR range.
Description
OverviewAnushakti HR-FR-LSH is the flagship PVC based house wire in the range, searched for as HR FR LSH wire or HRFR LSH. It puts both upgrades into one insulation: e-beam cross linked heat resistance for circuits that run warm, and a low smoke, low halogen compound for buildings where smoke would block a way out. Single core, 1100 V, 0.75 to 6 sq mm, in Class 2 and Class 5.
This is the grade to specify when you would rather not mix grades room by room. A high rise flat has both problems at once: kitchen and air conditioner circuits that stay warm, and a single enclosed staircase that everyone on the floor has to use. Hospitals, schools and offices are the same. It is made to IS 694:2010, and the published fire test values sit in the table further down this page.
Why this wire
Key benefitsCharacteristics
At a glance| Application | Residential, commercial and fire-sensitive wiring where safety and higher load capacity matter. |
|---|---|
| Characteristics | E-beam cross-linked HR FR-LSH insulation; heat-resistant to 105°C, flame-retardant, low smoke, zero halogen; melt- and short-circuit resistant. |
| Applicable standard | IS 694:2010 (exceeds minimum requirements). |
| Product range | Single-core, 1100 V grade, 0.75 – 6 sq mm (Class 2 & Class 5). |
| Advantages | Up to 50% more current-carrying capacity; ~50-year service life; energy-saving; halogen-free. |
Construction
Cutaway- 1Class 2 / Class 5 copper conductorElectrolytic-grade annealed bare copper, stranded for flexibility
- 2E-beam cross-linked HR FR-LSH insulationHeat-resistant to 105°C, flame-retardant, low smoke and zero halogen
- 3Printed identification & ISI markingGrade, size, 1100 V, IS 694 and BIS licence number
Dimensions & ratings
Technical data| Size (sq mm) | Construction | Insulation (mm) | O.D. (mm) | Resistance (Ω/km) | In conduit (A) | Clipped (A) |
|---|---|---|---|---|---|---|
| 0.75 / Class 5 | 24/0.2 | 0.6 | 2.20 | 26 | 11 | 16 |
| 1 / Class 2 | 7/0.43 | 0.7 | 2.70 | 18.1 | 16 | 24 |
| 1 / Class 5 | 32/0.2 | 0.6 | 2.40 | 19.5 | 16 | 24 |
| 1.5 / Class 2 | 7/0.53 | 0.7 | 3.00 | 12.1 | 20 | 32 |
| 1.5 / Class 5 | 30/0.25 | 0.7 | 2.85 | 13.30 | 20 | 32 |
| 2.5 / Class 2 | 7/0.67 | 0.8 | 3.60 | 7.41 | 27 | 44 |
| 2.5 / Class 5 | 50/0.25 | 0.8 | 3.50 | 7.98 | 27 | 44 |
| 4 / Class 2 | 7/0.85 | 0.8 | 4.10 | 4.61 | 36 | 58 |
| 4 / Class 5 | 56/0.3 | 0.8 | 4.0 | 4.95 | 36 | 58 |
| 6 / Class 2 | 7/1.04 | 0.8 | 4.70 | 3.08 | 47 | 74 |
| 6 / Class 5 | 84/0.3 | 0.8 | 4.50 | 3.30 | 47 | 74 |
| Temperature index | Oxygen index | Smoke density | Acid gas |
|---|---|---|---|
| ≥ 250°C | > 29% | 75% | 20% |
Standards & approvals
ComplianceManufactured and tested to IS 694:2010, the Indian Standard for PVC-insulated cables for working voltages up to and including 1100 V. Every drum is ISI-marked and BIS-certified.
Flame-retardant, low-smoke, low-halogen grade as defined in IS 694:2010, with e-beam cross-linked insulation tested beyond the standard's minimum requirements.
The BIS licence number is printed along the wire, so an electrician or buyer can verify a genuine product at the point of sale.
Applications
Where it's usedUse the APAR Wire-Size Calculator to size a circuit in seconds.
Documents
DownloadsFAQs
Good to knowWhat does HR FR LSH mean?+
HR FR LSH stands for Heat-Resistant, Flame-Retardant, Low Smoke and Halogen. It resists flame spread, emits very low smoke and no toxic halogen gases in a fire, and withstands high operating temperatures without insulation failure.
How is it different from ordinary house wire?+
It is made with Electron Beam (E-beam) technology, which cross-links the insulation for up to 50% more current-carrying capacity, heat resistance to 105°C, and melt/short-circuit resistance — well beyond conventional PVC wires.
Where is it best used?+
Ideal for residential and commercial buildings, distribution boards, appliance and control-panel wiring, and fire-sensitive environments such as hospitals and institutions.
What is the service life?+
Its E-beam cross-linked insulation gives a service life of over 50 years under normal operating conditions.
What is HR FR LSH wire?+
A house wire whose PVC insulation is heat resistant (HR), flame retardant (FR) and low smoke and halogen (LSH). You get the higher temperature rating of HR-FR plus the low-smoke behaviour of FR-LSH in a single wire.
Is HR-FR-LSH the same as ZHFR or HFFR?+
No. HR-FR-LSH is a low-halogen PVC compound. ZHFR, HFFR and LSZH are halogen-free compounds that are not PVC at all. If you need halogen-free, look at the Anushakti Fire Protekt (EBXL HFFR) page. If you need heat resistance and low smoke at a PVC price point, HR-FR-LSH is the grade.
Which rooms or circuits should use HR-FR-LSH?+
Kitchens, geyser and AC circuits in apartments, any run through a common stairwell or corridor, and whole-house wiring where the owner wants one grade everywhere rather than mixing FR and FRLS. Size it with the calculator on this site.
Sizing or selecting a cable? Browse our guides & charts →