APAR Anushakti Fire Protekt EBXL HFFR (XZ)
House Wires & Cables · Flagship

APAR Anushakti Fire Protekt EBXL HFFR (XZ)

India's safest house wire — e-beam, halogen-free.
Made with Electron Beam technology: flame-retardant, halogen-free insulation that resists heat, emits very low smoke, carries up to 100% more current, and lasts around 70 years.
InsulationHFFR, halogen-free
Voltage grade1100 V
Operating temp−30°C to +120°C
Sizes0.75 – 6 sq mm
Share
IS 694:2010
ISI / BIS
RoHS
REACH
CPRI tested
ISO 9001

Description

Overview

Anushakti Fire Protekt is APAR's flagship fire-safe house wire, engineered with Electron Beam (e-beam) technology. Its halogen-free insulation resists flame and heat, emits very low smoke and zero toxic gas, and is built to last.

Made with Electron Beam technology: flame-retardant, halogen-free insulation that resists heat, emits very low smoke, carries up to 100% more current, and lasts around 70 years.

Applications

Where it's used
High-rise & residential towersHospitals & healthcareSchools & institutionsMetros & railwaysData centresMalls & commercial
Not sure which size you need?

Use the APAR Wire-Size Calculator to size a circuit in seconds.

Open calculator →

Construction

Cutaway
123
  1. 1
    Class-2 bright copper conductor99.97% electrolytic-grade copper, stranded for flexibility
  2. 2
    E-beam cross-linked HFFR insulationHalogen-free, low-smoke, melt- & heat-resistant to 120°C
  3. 3
    Printed identification & ISI markingGrade, size, 1100 V, IS 694 and BIS licence number

Characteristics

At a glance
ApplicationHigh-rises, hospitals, schools, metros, data centres and fire-sensitive residential & commercial wiring.
CharacteristicsE-beam cross-linked HFFR insulation; halogen-free, low smoke; melt-resistant; anti-termite; 120°C operating, 250°C short-circuit.
Applicable standardsIS 694:2010.
Product rangeSingle-core, 1100 V grade, 0.75 – 6 sq mm.
AdvantagesUp to 100% more current capacity*; ~70-year life; zero halogen; high oxygen index (≥ 31%).

Dimensions & ratings

Technical data
Conductor & current rating
Size (sq mm)ConstructionInsulation (mm)O.D. (mm)Resistance (Ω/km)
0.7524/0.210.62.3026.0
1.530/0.260.62.7013.3
2.550/0.260.73.407.98
4.056/0.310.84.004.95
6.084/0.310.84.603.30
Fire performance
Temperature indexOxygen indexSmoke densityAcid gas
≥ 250°C≥ 31%≤ 10%≤ 0.5%

Standards & approvals

Compliance

Manufactured and tested to IS 694:2010, ISI-marked and BIS-certified. The BIS licence number is printed along the wire as proof of a genuine product.

Printed on the cable
APAR ANUSHAKTI FIRE PROTEKT · 1100V · IS 694 · ISI CM/L-XXXXXXX

FAQs

Good to know

What are the main safety advantages?+

HFFR insulation emits minimal smoke and zero toxic halogen gases in a fire, improving evacuation visibility and protecting equipment.

Where is it best installed?+

Fire-alarm and emergency-lighting circuits, building management systems, railway signalling, airports, malls and busy commercial complexes.

What certifications does it carry?+

Complies with IS 694:2010 and has undergone rigorous testing for quality, safety and performance.

Request information

Get a quote

Request a quote

Tell us your requirement — our team will get back to you.

Enquiry about: APAR Anushakti Fire Protekt EBXL HFFR (XZ) · House Wires and Cables

Your details are used only to respond to this enquiry. We never share them with third parties.

Get APAR Anushakti Fire Protekt EBXL HFFR (XZ)

Enquire for pricing, request the datasheet, or find your nearest authorised dealer.