APAR Anushakti Fire Protekt EBXL HFFR (XZ)
Description
OverviewAnushakti Fire Protekt is APAR's flagship fire-safe house wire, engineered with Electron Beam (e-beam) technology. Its halogen-free insulation resists flame and heat, emits very low smoke and zero toxic gas, and is built to last.
Made with Electron Beam technology: flame-retardant, halogen-free insulation that resists heat, emits very low smoke, carries up to 100% more current, and lasts around 70 years.
Why this wire
Key benefitsCharacteristics
At a glance| Application | High-rises, hospitals, schools, metros, data centres and fire-sensitive residential & commercial wiring. |
|---|---|
| Characteristics | E-beam cross-linked HFFR insulation; halogen-free, low smoke; melt-resistant; anti-termite; 120°C operating, 250°C short-circuit. |
| Applicable standards | IS 694:2010. |
| Product range | Single-core, 1100 V grade, 0.75 – 6 sq mm. |
| Advantages | Up to 100% more current capacity*; ~70-year life; zero halogen; high oxygen index (≥ 31%). |
Construction
Cutaway- 1Class-5 flexible copper conductor99.97% electrolytic-grade copper, stranded for flexibility
- 2E-beam cross-linked HFFR insulationHalogen-free, low-smoke, melt- & heat-resistant to 120°C
- 3Printed identification & ISI markingGrade, size, 1100 V, IS 694 and BIS licence number
Dimensions & ratings
Technical data| Size (sq mm) | Construction | Insulation (mm) | O.D. (mm) | Resistance (Ω/km) |
|---|---|---|---|---|
| 0.75 | 24/0.20 | 0.6 | 2.30 | 26.0 |
| 1.5 | 30/0.25 | 0.6 | 2.70 | 13.3 |
| 2.5 | 50/0.25 | 0.7 | 3.40 | 7.98 |
| 4.0 | 56/0.30 | 0.8 | 4.00 | 4.95 |
| 6.0 | 84/0.30 | 0.8 | 4.60 | 3.30 |
| Temperature index | Oxygen index | Smoke density | Acid gas |
|---|---|---|---|
| ≥ 250°C | ≥ 31% | ≤ 10% | ≤ 0.5% |
Standards & approvals
ComplianceManufactured and tested to IS 694:2010, the Indian Standard for PVC-insulated cables for working voltages up to and including 1100 V. Every drum is ISI-marked and BIS-certified.
The e-beam cross-linked HFFR insulation is tested beyond the minimum requirements of the standard for oxygen index, smoke density and halogen content.
The BIS licence number is printed along the wire, so an electrician or buyer can verify a genuine product at the point of sale.
Applications
Where it's usedUse the APAR Wire-Size Calculator to size a circuit in seconds.
Documents
DownloadsFAQs
Good to knowWhat are the main safety advantages?+
HFFR insulation emits minimal smoke and zero toxic halogen gases in a fire, improving evacuation visibility and protecting equipment.
Where is it best installed?+
Fire-alarm and emergency-lighting circuits, building management systems, railway signalling, airports, malls and busy commercial complexes.
What certifications does it carry?+
Complies with IS 694:2010 and has undergone rigorous testing for quality, safety and performance.