APAR Tarang Shakti Lan Cables
Description
OverviewTarang Shakti LAN cable is a Cat 6 UTP networking cable: four twisted pairs of 24 AWG solid copper, tested to 250 MHz and ready for Gigabit Ethernet. Solid conductors and a consistent twist rate are what hold crosstalk down across a full length permanent link, which is where cheaper cable starts failing certification.
Use it for structured cabling in offices and campuses, home and smart home networks, switch and router links, and data centre patching. It follows ANSI/TIA-568.2-D and ISO/IEC 11801, and comes as unarmoured FR PVC or wire armoured LSZH on 305 m boxes. Keep the bend radius to at least four times the cable diameter on a fixed run, and hold the permanent link to 90 m.
Why this wire
Key benefitsCharacteristics
At a glance| Type | LAN networking cable, Cat 6 UTP. |
|---|---|
| Bandwidth | Up to 250 MHz — Gigabit Ethernet ready. |
| Construction | Class 1 solid copper conductor, HDPE insulation, aluminium-foil screen, PE sheath. |
| Temperature rating | -20°C to +60°C. |
| Minimum bend radius | 4 × OD (fixed), 8 × OD (flexed). |
| Colour | Grey (black on armoured LSZH). |
Construction
Cutaway
- 1Solid bare copper conductor24 AWG (0.51 mm), high-conductivity electrolytic grade
- 2HDPE insulationSolid polyethylene, colour-coded to standard pair sequence
- 3Four twisted pairs with central cross-fillerDifferential lay lengths and a spline to control crosstalk
- 4Polyester binder tape and ripcordHolds the core round, allows clean stripping
Dimensions & ratings
Technical data| Cable type | Category | Packing |
|---|---|---|
| Cat 6 UTP Unarmoured, FR PVC | 24 AWG Cat 6 | 305 m |
| Cat 6 UTP Wire-Armoured, LSZH | 24 AWG Cat 6 | 305 m |
Standards & approvals
ComplianceBuilt to the Category 6 requirements of ANSI/TIA-568.2-D and ISO/IEC 11801: four twisted pairs, 24 AWG solid copper conductors and performance verified to 250 MHz, supporting Gigabit Ethernet over the full 100 m channel.
Every drum is tested for attenuation, near-end crosstalk (NEXT), return loss and impedance before dispatch. An LSZH-sheathed variant is available where the building's fire strategy calls for low smoke and zero halogen.
IS 694:2010 and the ISI mark do not apply to data cables — that standard covers PVC-insulated power and lighting cables.
Applications
Where it's usedUse the APAR Wire-Size Calculator to size a circuit in seconds.
Documents
DownloadsFAQs
Good to knowWhat category is the APAR LAN cable?+
It is a Cat 6 UTP cable with four twisted copper pairs, rated for bandwidth up to 250 MHz and suitable for Gigabit Ethernet.
What is the difference between the two variants?+
One is an unarmoured FR PVC cable for indoor use; the other is a wire-armoured LSZH cable for extra mechanical protection and low smoke, zero halogen performance.
What is the maximum run length?+
Like standard structured cabling, Ethernet channels are designed for up to 100 m; the cable is supplied in 305 m boxes.
What conductor does it use?+
A Class 1 solid copper conductor with HDPE insulation, an aluminium-foil screen and a PE outer sheath.
Sizing or selecting a cable? Browse our guides & charts →
Request information
Get a quoteRequest a quote
Tell us your requirement — our team will get back to you.
Enquire for pricing, request the datasheet, or find your nearest authorised dealer.