Skip to main content

Home Electrical Load Calculation Guide (kW to Wire Size)

Add up your appliance loads and translate the total into the right wire size.

Sizing the mains and circuits starts with knowing your total connected load. Here is the simple method.

Step 1 — Add up appliance wattages

ApplianceTypical power
LED lights & fans10–75 W each
Refrigerator150–350 W
Television50–150 W
Microwave1000–1500 W
1.5-ton air conditioner1500–1800 W
Geyser / water heater2000–3000 W
EV home charger3300–7400 W

Step 2 — Apply a diversity factor

You never run everything at once, so multiply the grand total by a diversity factor of about 0.6–0.8 to get a realistic maximum demand.

Step 3 — Convert to current

For a single-phase 230 V supply, current (A) = power (W) ÷ 230. For example, a maximum demand of 6 kW ≈ 26 A, which points to a 6 sq mm copper main and an appropriately rated main switch.

Step 4 — Size each circuit

Give heavy appliances (AC, geyser, EV charger) their own dedicated circuit and wire size, and keep lighting and general sockets on separate circuits. Use our appliance wire-size chart and MCB-to-wire chart to finish the job.

Indicative guidance for typical Indian domestic installations. Always confirm final cable sizes against the applicable IS standards, your local wiring rules and a licensed electrician for your specific installation.

Take this with you. Download the printable PDF version of this reference.
Download PDF