Can new wires be pulled through the existing conduit during a renovation?

Quick answer

Often, yes, provided the conduit is sound and has room. Drawing new wires through the existing concealed conduit avoids cutting the walls open, and it is the usual method where the conduit is continuous and the junction boxes can be reached.

Three checks decide it. The conduit must be clear, because crushed sections, sharp bends and boxes filled with plaster stop a draw wire. It must have space, because extra circuits or larger sizes for an air conditioner or an induction hob can overfill it, which traps heat and scrapes the insulation during the pull. The conduit fill chart gives the limits. And the old wires should be drawn out, not left beside the new ones.

Where the conduit fails any of these checks, a new route is the safer answer. APAR house wires are published in sizes from 0.5 to 16 sq mm across the range.